Abbott - Architect Plus ci4100 Processing Module (Integrated)

SKU: C400622; i15R04092
Stock: 2
Price:
$74,000.00

Qty: - +

Abbott Architect Plus ci4100 Chemistry Analyzer Processing Module (Integrated)


Used - unit is in outstanding working condition, please see photos for details. Includes everything pictured. Unit will be tested before shipping. Comes with our 30-day, 100% no hassle warranty.

This unit has always been under service contract and is only 5 years old. It retails $150k brand new.

The ARCHITECT ci4100 combines ARCHITECT c4000 and ARCHITECT i1000SR instruments − offering lower volume laboratories the enhanced efficiency and productivity employed by larger volume laboratories.

The ARCHITECT ci4100 offers a maximum throughput of up to 900 tests per hour, including 800 clinical chemistry and 100 immunoassay tests. Featuring a load-up capacity of 180 samples with 35 priority positions, the ARCHITECT ci4100 has up to 115 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).

For in vitro diagnostic use only.

SPECIFICATIONS:

Methods      c4000: Photometric, Potentiometric, Turbidimetric; i1000SR: CHEMIFLEX     
Maximum Throughput  Up to 900 tests/hour 
Sample Types 

c4000: Serum, Plasma, Whole Blood, Urine, CSF; i1000SR: Serum, Plasma, Whole Blood, Urine

Sample Tubes  Height: 72–102 mm Diameter: 9.6–16.1 mm 
Sample Cup  Yes (50 µL dead volume) 
Sample Capacity  180 
Sample Barcode Types  Code 39, Codabar, Interleaved 2 of 5, Code 128 
Sample Result Storage  50,000 
Sample Volume  c4000: 1.5–35 µL Average: 6 µL; i1000SR: 10–150 µL Average: 62 µL 
Automatic Dilution Yes 
Sample Probe Carryover   ≤0.1 parts per million 
Reagent Capacity  Up to 115 refrigerated positions plus patented ISE (Na+, K+, and Cl-) 
Reagent Type  c4000: >95% liquid ready-to-use; i1000SR: >100% liquid ready-to-use 
Reagent Onboard Stability c4000: 5–65 days Average: 40 days; i1000SR: 14-30 days 
Calibration Frequency   c4000: 1–60 days Average: 25 days; i1000SR: Calibrate with new lot number, if controls are out of range or if specified otherwise within the package insert 
Sample, Clot and Bubble Detection  Yes 
Reagent Pressure Monitoring  Yes 
Sample Interference Measurement  Yes, hemolysis, icterus, and lipemia 
System Control Center  1 SCC, with color touchscreen monitor, keyboard, and mouse 
Onboard Maintenance Records   Yes 
Online Error Code Help  Yes 
Host Interface  Bidirectional, serial RS-232 interface, host query option available 
Remote Diagnostics  AbbottLink 
Dimension (H x W x D)  49" x 111" x 36" 125.1 x 281.2 x 90.7 cm 
Weight  1,677 lbs 760.7 Kg 
Electrical Requirements  c4000: AC 180-264V, 47-63 Hz, 20 amp; i1000SR: AC 110-120V or 200-240V, ±10%, 50 or 60 Hz self-adjusting 
Water Requirements c4000: Deionized water 15 liters/hour during normal operation, 25 liters/hour maximum; i1000SR: Purified water to dilute buffer concentrate 
Heat Output*  c4000: 3050 BTU/hr, running mode; i1000SR: 2400 BTU/hr, running mode 
Sample Loading   RSH 

*Values provided represent the typical output in “Running” mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics.